Waters NanoACQUITY UPLC with ACQUITY 2996 PDA

  0SY-Waters-0390
 
Waters NanoACQUITY UPLC with ACQUITY 2996 PDA
Waters NanoACQUITY UPLC with ACQUITY 2996 PDA
Waters NanoACQUITY UPLC with ACQUITY 2996 PDA
Waters NanoACQUITY UPLC with ACQUITY 2996 PDA
Waters NanoACQUITY UPLC with ACQUITY 2996 PDA
  This Refurbished Waters NanoAcquity UPLC System with Waters ACQUITY 2996
PDA come with the following:
  • Waters Acquity 2996 PDA with Nano scale flow cell installed 
  • Waters NanoAcquity Binary Solvent Mamager
  • Waters NanoAcquity Sample Manager with attached column oven
  • Waters Sample Tray
  • Essential cables for full operation
Maximum resolution – optimized system to drive 1.7 µm BEH particle technology to yield maximum peak capacity for complex mixtures.
Maximum reproducibility – direct nanoflow control and a novel, movable heating and trapping module for <0.25-minute standard deviation run-to-run reproducibility, even overlong gradients
Maximum throughput – BEH Technology columns enable faster gradient separations for simple mixtures, or when preforming targeted analyses without compromising resolution
Robustness – Nano-scale columns and fittings (PEEK, 1/32 stain-less steel and goal coating)provide reliable operation for up to 10,000 psi, with novel pressure trapping
Ease-of-use – Direct gradient control enables minimized tubing assembles and simplified loading and trapping schemes.
Enhanced on-board diagnostics – Efficiently monitor system performance
Combine with any MS – Control the NanoAcquity UPLC system from your Waters, Thermo Fisher Scientific,or ABI/MDS SCIEX mass spectrometer software platforms
UPLC and HPLC – Compatible with a wide range of conventional nano-scale columns with a flow range from 200 nL/min to 100 µL/min 

Acquity 2996 PDA

Item Specification
Wavelength range 190 to 800 nm
Light source Prealigned, Deuterium lamp
Spectral Resolution/Optical Bandpass 1.2 nm per photodiode with a total of 512 photodiodes, digital and optical (3D-mode)
Digital Resolution   1.2 nm – 600 nm (2D mode)
Wavelength accuracy ±1 nm
Linearity range 5% at 2.0 AU, propylparaben, at 256 nm
Spectral resolution 1.2 nm
Baseline noise ±1.5 × 10–5 AU peak-to-peak, dry, at 254 nm
Drift 1 × 10–3 AU/hour at 254 nm (after warm-up) ∆T  1°C per hour
Operation temperature 4 to 40 °C (39 to 104 °F), not to vary more than 1 °C per hour (to prevent drift)
Relative humidity 20 to 80%, noncondensing
Power Grounded ac, 100 to 240 Vac
Power requirements 100-230 VAC
Frequency range 50 to 60 Hz
Path Length 10 mm (standard analytical cell)
Cell volume 8 µl (standard analytical cell)
Pressure Limit 1000 psi (standard analytical cell)
Wetted materials 316 stainless steel, fused silica Tefzel
Dimensions Width: 11.5 in. (29 cm)
Depth: 24 in. (61 cm)
Height: 8.5 in. (22 cm)
Weight 31.5 lbs (14.3 kg)

This Waters NanoAcquity UPLC with ACQUITY 2996 PDA is in good condition. 

A 90 day warranty is included.

We have special expertise on analytical equipment. We encourage you to contact us to speak with one of our expert and professional team members.

Thanks for looking and we look forward to hearing from you!
 
 
  Price: In Stock Call for Quote
  INQUIRE/OFFER
 
  We will match prices with our competitors
  Please Call Us at Toll Free Number:
1-866-777-3688 Tel: 905-946-8066
 
Contact by email at:
info@spectralabsci.com


 
The one stop shop for all your analytical laboratory needs!
Your source for PRE-OWNED Spectralab Scientific Inc. CERTIFIED Equipment.
We buy your laboratory or surplus analytical equipment:

Contact buy@spectralabsci.com

Trade-in service or analytical equipment:

available via info@spectralabsci.com


  Related Products:

Copyright © 2019 SpectraLab Scientific Inc. All right reserved. Please contact us by email at: info@spectralabsci.com

Being supported and modified by Spectralab, contact by email at:info@spectralabsci.com