This system includes:
- (1) Agilent 7820A Gas Chromatograph
- (1) Agilent 5977B GC/MSD Inert Plus G7077B
- (1) Agilent 7693A Auto Injector (G4513A)
- (1) Agilent 7693 Sample Vial Tray with 150 slots (G4513A)
- (1) Agilent Turbo Pump
- PC with MassHunter Software
The 7820A Gas Chromatograph system performs great day-to-day analysis. The system provides reliable capabilities for a wide range of application areas, meeting regulatory and SOP needs for small-to medium-sized labs.
Runs with full electronic pneumatic control (EPC) from inlet to detector for good retention time and area count performance. Electronic pneumatic regulation (EPR) offers manual operation simplicity with high precision digital display of pressure/flow. Superior ease-of-use over traditional systems.
Features:
- Retention Time Locking (RTL) provides improved data consistency by maintaining exact retention times from injection to injection, column to column, instrument to instrument, and lab-to-lab
- Electronic Pneumatics Regulation (EPR) provides the simplicity of manual operation with high-precision digital display of pressure/flow and superior ease-of-use, compared to traditional manual pneumatics systems
- Great fit for routine applications using a single quadrupole mass spectrometer
- Single filament TCD doesn’t require a separate reference gas or manual potentiometer adjustment and provides a stable baseline without drift
- Auto-ranging FID provides the ability to detect and quantitate from parts per billion (ppb) to parts per thousand in a single injection
- Inlets options include split/splitless, packed, purge packed, and on-column inlets
- Valve configurations that include up to three valves
- Full electronic pneumatic control (EPC) from inlet to detector
- Simplified GC front panel keys and display provide sequence information, instrument conditions,and run status, and minimize operating errors
- Software keyboard and display allows the user to control the system when it connects with an integrator or 3rd-party software
The Agilent 5977B GC/MSD is the latest in the series of most trusted Single Quadrupole GC/MS systems. Made for labs that focus on applications such as environmental, chemical, petrochemical, food, forensic, pharmaceutical, and material testing.
Building on a long track record of innovation, the High Efficiency Source (HES) and InertPlus Extractor EI Source maximize the number of ions that are created and transferred out of the source body and into the quadrupole analyzer. This novel Mass Selective Detector (MSD) design makes the 5977B the most popular GC/SQ for routine, robust and reliable use.
Features:
- Improve sensitivity (10x greater) with detection limits as low as 1.5 fg IDL, bringing yesterday’s triple-quadrupole limits of detection into today’s single quadrupole laboratory
- Reduce time spent on sample prep and maintenance, while meeting your current sensitivity requirements, with just 1/10 of the original sample volume
- Minimize operating and shipping costs by storing, prepping, and disposing of 10x less material
- Benefit from eco-friendly features, such as Sleep/Wake modes, and conserve electricity and other resources like carrier gas
- Greatly reduce or even eliminate the need for manual source cleaning with the JetClean self-cleaning ion source
- The built-in intelligence of the 8890 GC drives productivity with diagnostics, monitoring, and simplified access to powerful operations through the integrated touchscreen and browser interface
- Inert Flow Path provides improved performance for sensitive analytes at low levels, extending the range of quantitation and detection
- Simplify method development, from instrument settings to data analysis and reporting with MassHunter Software
The Agilent 7693A ALS (Automatic Liquid Sampler) provides reliable, fast, and precise injections for Agilent GC and GC/MS systems. The modular design allows this autosampler to grow with your lab.
Start with a tower and 16 vials. Expand to the 150 vial tray. Upgrade to the heater, mixer barcode reader module. Add a second tower for dual simultaneous injections.
Features:
- 150 sample vial tray allows longer unattended operation
- Dual simultaneous injection saves time by doubling sample throughput
- Fast injection technology minimizes needle discrimination and enables use of external standards
- Sandwich injections of three layers eliminate manual error from internal standard, surrogate, or protectant additions
- Sample heater and mixer dramatically improves high molecular weight chromatographic results
- Heat the entire tray or cool it to sub-ambient temperatures to meet your lab’s needs
- Modular design allows the flexibility to easily move the sampler from GC to GC or start with a single injector and upgrade as needed
- Priority sample capability. There is no need to stop the sequence to add next most important sample
- Barcode reader allows the system to perform specific actions on mismatch, ensuring chain of custody Agilent Barcode Printing Solution.