This Set includes:
- (1) Agilent 7890B GC
- (1) Agilent 7000C Triple Quadrupole Mass Spectrometer G7011A
- (1) Agilent LTM (Low Thermal Mass) Series II Rapid Heating/Cooling System
- (1) Agilent G6501B GC Sampler 80
- (1) Edwards Rotary Vane Pump RV5
- (1) PC with data
Agilent 7890B GC
- Retention Time Locking (RTL) maintains exact retention times from injection to injection, column to column, instrument to instrument, and lab to lab
- Capillary Flow Technology (CFT) provides unique instrument capabilities, such as multi-dimension gas chromatography (GC-GC/Deans Switch), comprehensive two-dimension gas chromatography (GCxGC) with flow modulation, and backflush at the beginning, middle, or end of the analytical column
- Single filament TCD that does not require a separate reference gas, does not require manual potentiometer adjustment, and provides a stable baseline with a minimal amount of signal drift
- Auto-ranging FID provides the ability to detect and quantitate from parts per billion (ppb) to parts per thousand in a single injection
- Integrated SCD/NCD (sulfur or nitrogen chemiluminescence detector) provides low ppb detection, equi-molar response, and quantitation for sulfur or nitrogen contaminants without quenching from matrix
- Carrier Gas Options: Helium Conservation Module, Hydrogen Sensors and Alternate Carrier Gas Solutions dramatically reduce the amount of helium used to offer flexibility in your laboratory
- Large Valve Oven (LVO) allows for the combination of multiple methods and simplified maintenance
- Multimode inlet (MMI) serves as a programmable temperature vaporizing injector with flexible capabilities
- Agilent Inert Flow Path provides increased sensitivity for active compounds, from injection to detection
- Low Thermal Mass (LTM) modules, up to 4 installed and operating, increase sample throughput with rapid column heating and cooling
Agilent 7000C QQQ
The 7000C Triple Quadrupole GC/MS was designed to deliver the most accurate quantitative results and confident identification even in the most complex matrices. The 7000C GC/MS system’s 4fg OFN Instrument Detection Limit (IDL) is demonstrated upon installation verifying unmatched ALS, GC and MS performance. Coupled with the 7890B GC, the 7000C MS works in perfect harmony to enhance productivity, save resources and alert operators about pending maintenance.
Agilent GC Sampler 80
The Agilent PAL injection system lets you change injectors quickly, allowing you to perform the following techniques on a single autosampler. The sample injection system combines liquid, headspace, and SPME injection into one instrument, allowing you to quickly switch from one application to another on the same GC workstation. So whether you process samples in headspace, liquid or SPME mode – if your method requires split/splitless or on column injection – your instrument setup can be ready in minutes.
Edwards Rotary Vane Pump RV5
Displacement | |
50Hz | 5.8 m3h-1 / 3.4 ft3min-1 |
60Hz | 7.0 m3h-1 / 4.1 ft3min-1 |
Speed (Pneurop 6602) | |
50Hz | 5.1 m3h-1 / 3.0 ft3min-1 |
60Hz | 6.2 m3h-1 / 3.7 ft3min-1 |
Ultimate pressure | 2.0 x 10-3 mbar / 1.5 x 10-3 Torr |
Ultimate pressure GB I | 3.0 x 10-2 mbar / 2.3 x 10-2 Torr |
Ultimate pressure GB II | 1.0 x 10-1 mbar / 7.5 x 10-2 Torr |
Ultimate Pressure with Fomblin® | 2.0 x 10-2 mbar / 1.5 x 10-2 Torr |
Max inlet pressure for water vapour | 50 mbar / 38 Torr |
Max water vapour pumping rate – GB I | 60 gh-1 |
Max water vapour pumping rate – GB II | 220 gh-1 |
Max allowed outlet pressure | 0.2 bar gauge / 2.8 psig |
Max allowed inlet and gas ballast pressure | 0.5 bar gauge / 7 psig |
Motor power 50/60Hz | 450 / 550W |
Power connector 1-ph | IEC EN60320 C13 |
Nominal rotation speed 50/60Hz | 1500 / 1800rpm |
Weight (without oil) | 25 kg / 55 lb |
Oil capacity min/max | 0.42/0.7 litres |
Recommended oil | Ultragrade 19 |
Inlet flange | NW25 |
Exhaust flange | NW25 |
Noise level | 48 dB(A) @ 50 Hz |
Operating temperature range | 12 – 40 °C |