The Shimadzu Nexera X2 is a flexible system design achieves a true fusion between UHPLC and HPLC technologies, enabling the Nexera X2 to be used for a much broader range of applications. This UHPLC system not only offers maximum speed, sensitivity, resolution, stability, and reliability, it also features a revolutionary i-PDeA separation technology and an i-DReC function that extends the dynamic range so that both concentrated and trace components can be quantitated simultaneously.
System Includes:
- (1) Shimadzu Nexera X2 SPD-M30A Photodiode Array Detector
- (2) Shimadzu Nexera X2 LC-30AD Pump
- (1) Shimadzu Prominence DGU-20A5R Degassing Unit
- (1) Shimadzu CBM-20A Communications Bus Module
- (1) Shimadzu Nexera SIL-30AC Autosampler
- (1) Shimadzu Nexera X2 CTO-30A Column Oven
- (1) PC with Data Software
Shimadzu Nexera X2 SPD-M30A Photodiode Array Detector
- High level spectral resolution
- A new i-PDeA function that enables peak separation
- High level sensitivity and outstanding separation performance
- Superior stability
Shimadzu Nexera X2 LC-30AD Pump
Degassing Unit | 3 or 5 Lines (Volume 400 μL) |
---|---|
Flow rate range | 0.0001 to 10 mL/min |
Flow rate precision | No more than 0.06% RSD or 0.02 min SD, whichever is greater |
Gradient type | High-pressure / low-pressure mixing gradient |
Gradient / concentration precision | ±0.5% (specified conditions) |
Maximum pressure | 130 MPa (0.0001 to 3 mL/min) 80 MPa (3.0001 to 5 mL/min) 22Mpa (5.0001 to 10 mL/min) |
Shimadzu Prominence DGU-20ASR Degassing Unit
- <400 uL internal volume
- Plugs into LC-20A/LC-30A series pump for power and control
- New material (Systec AF®) allows high gas permeability
- Peak efficiency in under 1 minute
- Additional channel provided for autosampler rinse solution
Shimadzu CBM-20A Communications Bus Module
Connectable Units | Solvent delivery units: 4 max; Autosamplers: 1; Column ovens: 1; Detectors: 2 max; Fraction collectors: 1; Sub-controllers: 2 max. |
Number of connectable units | 8 (expansion possible up to 12) |
Data Buffering | Approx. 24 hours for one analysis (at 500ms sampling rate;available only with LCsolution) |
Event I/O | 4 inputs, 4 outputs |
Analog Boards | Up to 2 boards can be mounted |
Operating temperature range | 4°C to 35°C |
Shimadzu Nexera SIL-30AC Autosampler
Injection method | Needle-in-flowpath |
---|---|
Injection volume accuracy | ±1% (at 50 μL injectiong, n = 10) |
Injection volume range | 0.1 to 50 μL (Option: 0.1 to 100 μL) |
Injection volume reproducibility | RSD: 0.3% maximum (at 10 μL) |
Samples capacity | Sample plate: 175 (1 mL), 105 (1.5 mL), 50 (4 mL), 2 (MTP/DWP plates) Control plate: 10 (1.5 mL) |
Sample cooler | Block cooling/heating, used together with defumidifying function 4 to 40°C |
Shimadzu Nexera X2 CTO-30A Column Oven
Oven Capacity | Up to 2 – 150 mm columns |
---|---|
Temperature control range | Room temperature ± 5 to 150°C, Setting range 4 to 150°C |