Agilent 7890B GC with Agilent 5977A GC/MS and 7693A Autosampler

Agilent 7890B GC with Agilent 5977A GC/MS and 7693A Autosampler
Item ID:

A7890B-A5977ADP-G4514A


Condition: Refurbished

Availability: In Stock

Manufacturer: Agilent (HP)Price:

Request Quote/ Offer

Warranty Included, Onsite/ Remote Installation and Training Available

Shipping:

CAN/US: 3-5 business days
International: 5-10 business days



For assistance and further information:

Toll Free: 1-866-777-3688
Tel: 905-946-8066
E-Mail: info@spectralabsci.com

Spectralab is your one stop shop for all your analytical laboratory needs!

Your source for

PRE-OWNED

and Spectralab Scientific

CERTIFIED

Equipment.

We will match our competitor's price!

To Sell, Trade in, or Service Your Equipment

This set includes:

  • (1) Agilent 7890B
  • (1) Agilent 5977A with diffusion pump
  • (1) Agilent G4513A Autoinjector
  • (1) Agilent G4514A 7693A Autosampler with 150 position Tray
  • (1) Edwards Rotary Vane Pump RV5
  • Mass Hunter Data Software

Agilent 7890B GC

  • Retention Time Locking (RTL) maintains exact retention times from injection to injection, column to column, instrument to instrument, and lab to lab
  • Capillary Flow Technology (CFT) provides unique instrument capabilities, such as multi-dimension gas chromatography (GC-GC/Deans Switch), comprehensive two-dimension gas chromatography (GCxGC) with flow modulation, and backflush at the beginning, middle, or end of the analytical column
  • Single filament TCD that does not require a separate reference gas, does not require manual potentiometer adjustment, and provides a stable baseline with a minimal amount of signal drift
  • Auto-ranging FID provides the ability to detect and quantitate from parts per billion (ppb) to parts per thousand in a single injection
  • Integrated SCD/NCD (sulfur or nitrogen chemiluminescence detector) provides low ppb detection, equi-molar response, and quantitation for sulfur or nitrogen contaminants without quenching from matrix
  • Carrier Gas Options: Helium Conservation Module, Hydrogen Sensors and Alternate Carrier Gas Solutions dramatically reduce the amount of helium used to offer flexibility in your laboratory
  • Large Valve Oven (LVO) allows for the combination of multiple methods and simplified maintenance
  • Multimode inlet (MMI) serves as a programmable temperature vaporizing injector with flexible capabilities
  • Agilent Inert Flow Path provides increased sensitivity for active compounds, from injection to detection
  • Low Thermal Mass (LTM) modules, up to 4 installed and operating, increase sample throughput with rapid column heating and cooling

Agilent 5977A GC/MS

  • Extractor Ion Source
    • The ‘push-pull’ principle of the Extractor Ion Source delivers more ions to the mass analyzer and increases confidence of your trace analysis methods.
  • Instrument Detection Limit (IDL)
    • Replace signal-to-noise ratio (S/N) with the new industry standard that measures the true sensitivity of your mass spec instrument.
  • Heated Gold Quadrupole
    • The quartz, hyperbolic monolithic is the only mass filter that can be heated to 200°C without loss of resolution or mass accuracy.
  • Triple-Axis Detector (TAD)
    • Optimizes signal-to-noise by combining efficient ion collection and amplification with the elimination of neutral noise.
  • GCMSD MassHunter with MSD ChemStation Data Analysis
    • Supports the MassHunter data analysis workflow for all instruments and the classic MSD ChemStation workflows for your GC/MSD and GC only operation.
  • Accurate Mass Data
    • The combination of Agilent’s proprietary quadrupole with MassWorks Software produces reproducible, highly accurate mass information, effective noise filtering, and unbiased baseline correction.
  • Integrated GC-MSD Communication
    • The 7890B GC and 5977A MSD ‘talk’ continuously and form a unified system that supports the highest productivity for your laboratory.
  • Sleep/Wake Mode
    • In sleep mode, you can reduce your energy costs and the system scheduler will wake the GC/MSD and ready it for your next work day.
  • Programmable Helium Conservation Module
    • Reduces helium consumption for GC and GC/MS systems by changing to an alternate carrier during system stand-by.
  • Safety Protection
    • If the MSD shuts down unexpectedly, GC gas flow is automatically terminated, ensuring safe operation with hydrogen and eliminates waste of costly helium.
  • Parts Finder Tool
    • Quickly locate and order replacement parts for your Agilent instruments through an interactive user interface.

Agilent G413A Autoinjector

  • Dual simultaneous injection saves time by doubling sample throughput
  • Fast injection technology minimizes needle discrimination and sample degradation
  • Perform single-stroke injection of up to 50 µL using a 100 µL syringe; multiple injections are possible depending on your needs
  • Eliminate analyst-to-analyst variability and reduce rework using powerful sample preparation capabilities, including dilution, internal standard addition, heating, mixing, and solvent addition
  • Modular design allows the flexibility to easily move the sampler from GC to GC or start with a single injector and add on to the system as needed

Edwards Rotary Vane Pump RV5

Displacement
  50Hz 5.8 m3h-1 / 3.4 ft3min-1
  60Hz 7.0 m3h-1 / 4.1 ft3min-1
Speed (Pneurop 6602)
  50Hz 5.1 m3h-1 / 3.0 ft3min-1
  60Hz 6.2 m3h-1 / 3.7 ft3min-1
Ultimate pressure 2.0 x 10-3 mbar / 1.5 x 10-3 Torr
Ultimate pressure GB I 3.0 x 10-2 mbar / 2.3 x 10-2 Torr
Ultimate pressure GB II 1.0 x 10-1 mbar / 7.5 x 10-2 Torr
Ultimate Pressure with Fomblin® 2.0 x 10-2 mbar / 1.5 x 10-2 Torr
Max inlet pressure for water vapour 50 mbar / 38 Torr
Max water vapour pumping rate – GB I 60 gh-1
Max water vapour pumping rate – GB II 220 gh-1
Max allowed outlet pressure 0.2 bar gauge / 2.8 psig
Max allowed inlet and gas ballast pressure 0.5 bar gauge / 7 psig
Motor power 50/60Hz 450 / 550W
Power connector 1-ph IEC EN60320 C13
Nominal rotation speed 50/60Hz 1500 / 1800rpm
Weight (without oil) 25 kg / 55 lb
Oil capacity min/max 0.42/0.7 litres
Recommended oil Ultragrade 19
Inlet flange NW25
Exhaust flange NW25
Noise level 48 dB(A) @ 50 Hz
Operating temperature range 12 – 40 °C

Request Quote:

*We do not share your information*

Name
Company
Address (City, State)
Country
Email
Email Confirmation
Phone
Your Budget/ Offer
Enquiry

Quality
Our refurbished instruments are tested and repaired to meet factory specifications. We follow Installation Qualification, Operational Qualification, and Performance Qualification protocols (IQ, PQ and OQ).

Expertise
Our team of skilled technicians are experts at fixing analytical instruments. We have been working with Agilent, Waters, Perkin Elmer, Sciex, Shimadzu, and Thermo instruments for many years. We are constantly updating our knowledge with the latest technology and information to enable us to deliver the best support in the industry. We provide value added support and qualification/validation with all our instruments. We endeavor to develop strategic partnerships with our clients so that they consider our team as an extension of their employees. We are an affordable alternative to many normally expensive business projects.

Warranty and Support
We offer warranty on all refurbished instruments. Warranty starts at 3 months, with the option to extend the period. While your instrument is on warranty, we will provide Email (support@spectralabsci.com) and phone support and troubleshooting if you require assistance. If there is ever anything wrong with the equipment, we will replace it. Warranty begins from the date your equipment is successfully delivered. Any issues that occur during warranty should be reported immediately, describing the issues in as much detail as possible. Do not attempt to repair the equipment or involve a 3rd party without our express permission – this will result in voiding our warranty.

We will match our warranty duration with our competitors.

Installation and Training
If you purchase equipment from Spectralab Scientific, we offer installation and familiarization by our service technicians for an additional fee. If the instrument is particularly complicated, we highly recommend this service. If you’ve purchased less-complex equipment from us that you would like to install yourself, we can provide Team Viewer, email, or telephone support for no additional cost.

Large Inventory
We have a large inventory of equipment, components and parts in stock. You can find all the equipment you need for you lab in our store, as well as mix and match components for your systems.

International Shipping
We have sufficient export experience, including professional packing and proper documentation. Complementary shipping and handling can be applied upon immediate purchase. We include customs fees, brokerage, and duties for shipping to the US.

Price Matching & Discounts
Purchasing our refurbished instruments can save you anywhere from 30% to 90% compared to purchasing brand new. We will try to match or beat any price from our competitors, so feel free to inquire! Complementary shipping and handling can be applied upon immediate purchase.

Featured Products

  • New
    Shimadzu LCMS-8060 CL Triple Quadrupole Mass Spectrometer

    Shimadzu LCMS-8060 CL Triple Quadrupole Mass Spectrometer


    Condition:

    Refurbished

    Request QuoteView
  • New
    Agilent 8890 Gas Chromatograph G3540A

    Agilent 8890 Gas Chromatograph G3540A


    Condition:

    Refurbished

    Request QuoteView
  • NEW Thermo Dionex ASE 350 Accelerated Solvent Extractor


    Condition:

    Brand New

    Request QuoteView