Agilent 1100 Series HPLC System

Agilent 1100 Series HPLC System
Item ID:

AGI1100-9909024


Condition: Refurbished

Availability: In Stock

Manufacturer: Agilent (HP)Price:

Request Quote/ Offer

Warranty Included, Onsite/ Remote Installation and Training Available

Shipping:

CAN/US: 3-5 business days
International: 5-10 business days



For assistance and further information:

Toll Free: 1-866-777-3688
Tel: 905-946-8066
E-Mail: info@spectralabsci.com

Spectralab is your one stop shop for all your analytical laboratory needs!

Your source for

PRE-OWNED

and Spectralab Scientific

CERTIFIED

Equipment.

We will match our competitor's price!

To Sell, Trade in, or Service Your Equipment

Introduced in 1995, Agilent’s 1100 series HPLC system is an extremely popular HPLC. They are robust, durable, and versatile. The 1100 HPLC series supports efficient mixing and pulse-free pump action as well as advanced diagnostics and data analysis software. Many additional features include modular binary and quadrary pump configurations, a high speed proportioning valve, and pre-configured vacuum degasser, making the 1100 a high functioning reliable assett in the laboratory. The system is easy to use at a low cost.

This system includes:

This Agilent 1100 HPLC System is in great condition. It has been tested at SpectraLab Scientific.
A 90 day warranty is included.

Agilent 1100 Series HPLC System Manual PDFs


Performance Specifications

 

 

G1315 Diode Array Detector
Type Specification
Detection type 1024-element photodiode array
Light source Deuterium and tungsten lamps
Wavelength range 190 – 950 nm
Short term noise (ASTM) Single and Multi-Wavelength ± 1 × 10-5 AU at 254 and 750 nm
Drift 2 × 10-3 AU/hr at 254 nm
Linear absorbance range > 2 AU (upper limit)
Wavelength accuracy ± 1 nm
Wavelength bunching 1 – 400 nm
Slit width 1, 2, 4 , 8, 16 nm
Diode width < 1 nm
Flow cells Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
High pressure: 1.7 µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure maximum
500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
Control and data evaluation Agilent ChemStation for LC
Analog outputs Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
Communications Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
Safety and maintenance Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
GLP Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages.
Electronic records of maintenance and errors.
Verification of wavelength accuracy with built-in holmium oxide filter.
Housing All materials recyclable.
G1312A Binary Pump
Type Specification
Hydraulic system Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
Setable flow range Setpoints 0.001 – 5 ml/min, in 0.001 ml/min increments
Flow range 0.1 – 5.0 ml/min
Flow precision < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
Pressure Operating range 0 400 bar (0 – 5880 psi) up to 5 ml/min
Pressure pulsation < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa
Compressibility compensation User-selectable, based on mobile phase compressibility
Recommended pH range 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
Gradient formation High-pressure binary mixing, delay volume 180 – 480 µl without mixer, 600 – 900 µl with mixer, dependent on back pressure
Composition range 1 – 99 % or 5 µl/min per channel, whatever is greater
Composition precision < 0.2 % RSD, at 0.1 and 1 ml/min
Control and data evaluation Agilent ChemStation for LC
Analog output For pressure monitoring, 2 mV/bar, one output
Communications Controller-area network (CAN), GPIB, RS-232C, AP
Safety and maintenance Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system.
Low voltages in major maintenance areas.
GLP features Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages.
Electronic records of maintenance and errors.
Housing All materials recyclable.

 

G1329A Thermostated Autosampler (100 µl metering head)
Type Specification
GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
Communications Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Injection range 0.1 – 100 µl in 0.1 µl increments
Up to 1500 µl with multiple draw (hardware modification required)
Replicate injections 1 – 99 from one vial
Precision Typically < 0.5 % RSD of peak areas from 5 – 100 µl,
typically < 1 % RSD of peak areas from 1 – 5 µl
Minimum sample volume 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
Carryover Typically < 0.1 %, < 0.05 % with external needle cleaning
Sample viscosity range 0.2 – 50 cp
Replicate injections per vial 1 – 99
Sample capacity 100 × 2-ml vials in 1 tray
40 × 2-ml vials in ½ tray
15 × 6-ml vials in ½ tray (Agilent vials only)
Injection cycle time Typically 50 s depending on draw speed and injection volume

 

G1329A Thermostated Autosampler (900 µl metering head)
Type Specification
Pressure Operating range 0-20 MPa (0-200 bar, 0-2950 psi)
GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
Communications Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Injection range 0.1 – 900 µl in 0.1 µl increments (recommended 1 µl increments)
Up to 1800 µl with multiple draw (hardware modification required)
Replicate injections 1 – 99 from one vial
Precision Typically < 0.5% RSD of peak areas from 5 – 2000 µl,
typically < 1% RSD of peak areas from 2000 – 5000 µl,
Typically < 3% RSD of peak areas from 1 – 5 µl
Minimum sample volume 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
Carryover Typically < 0.1%, < 0.05% with external needle cleaning
Sample viscosity range 0.2 – 50 cp
Sample capacity 100 × 2-ml vials in 1 tray
40 × 2-ml vials in ½ tray
15 × 6-ml vials in ½ tray (Agilent vials only)
Injection cycle time Typically 50s depending on draw speed and injection volume

 

G1316A Thermostated Column Compartment
Type Specification
Temperature range 10 degrees below ambient to 80 °C
Temperature stability ± 0.15 °C
Temperature accuracy ± 0.8 °C
± 0.5 °C
Column capacity Three 30 cm
Warm-up/cool-down time 5 minutes from ambient to 40 °C
10 minutes from 40 – 20 °C
Dead volume 3 µl left heat exchanger
6 µl right heat exchanger
Dimensions (h × w × d) 140 × 410 × 435 mm
Weight 10.2 kg
Communications Controller-area network (CAN), GPIB, RS-232C, APG Remote:
ready, start, stop and shut-down signals, LAN optional
Safety and maintenance Extensive diagnostics, error detection and display (through
control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of
pumping system. Low voltages in major maintenance areas.
GLP features Column-identification module for GLP documentation of column type
Housing All materials recyclable

 

G1322A Degasser
Type Specification
Maximum flow rate 10 ml/min per channel
Number of channels 4
Internal volume per channel Typically 12 ml per channel
Materials in contact with solvent PTFE, PEEK
pH range 1 – 14
Analog output (AUX) For pressure monitoring, range 0 – 3V

Request Quote:

*We do not share your information*

Name
Company
Address (City, State)
Country
Email
Email Confirmation
Phone
Your Budget/ Offer
Enquiry

Quality
Our refurbished instruments are tested and repaired to meet factory specifications. We follow Installation Qualification, Operational Qualification, and Performance Qualification protocols (IQ, PQ and OQ).

Expertise
Our team of skilled technicians are experts at fixing analytical instruments. We have been working with Agilent, Waters, Perkin Elmer, Sciex, Shimadzu, and Thermo instruments for many years. We are constantly updating our knowledge with the latest technology and information to enable us to deliver the best support in the industry. We provide value added support and qualification/validation with all our instruments. We endeavor to develop strategic partnerships with our clients so that they consider our team as an extension of their employees. We are an affordable alternative to many normally expensive business projects.

Warranty and Support
We offer warranty on all refurbished instruments. Warranty starts at 3 months, with the option to extend the period. While your instrument is on warranty, we will provide Email (support@spectralabsci.com) and phone support and troubleshooting if you require assistance. If there is ever anything wrong with the equipment, we will replace it. Warranty begins from the date your equipment is successfully delivered. Any issues that occur during warranty should be reported immediately, describing the issues in as much detail as possible. Do not attempt to repair the equipment or involve a 3rd party without our express permission – this will result in voiding our warranty.

We will match our warranty duration with our competitors.

Installation and Training
If you purchase equipment from Spectralab Scientific, we offer installation and familiarization by our service technicians for an additional fee. If the instrument is particularly complicated, we highly recommend this service. If you’ve purchased less-complex equipment from us that you would like to install yourself, we can provide Team Viewer, email, or telephone support for no additional cost.

Large Inventory
We have a large inventory of equipment, components and parts in stock. You can find all the equipment you need for you lab in our store, as well as mix and match components for your systems.

International Shipping
We have sufficient export experience, including professional packing and proper documentation. Complementary shipping and handling can be applied upon immediate purchase. We include customs fees, brokerage, and duties for shipping to the US.

Price Matching & Discounts
Purchasing our refurbished instruments can save you anywhere from 30% to 90% compared to purchasing brand new. We will try to match or beat any price from our competitors, so feel free to inquire! Complementary shipping and handling can be applied upon immediate purchase.

Featured Products

  • New
    Shimadzu LCMS-8060 CL Triple Quadrupole Mass Spectrometer

    Shimadzu LCMS-8060 CL Triple Quadrupole Mass Spectrometer


    Condition:

    Refurbished

    Request QuoteView
  • New
    Agilent 8890 Gas Chromatograph G3540A

    Agilent 8890 Gas Chromatograph G3540A


    Condition:

    Refurbished

    Request QuoteView
  • NEW Thermo Dionex ASE 350 Accelerated Solvent Extractor


    Condition:

    Brand New

    Request QuoteView